This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
admin:datacenter [2019/06/07 18:01] peppe [HP DL380G6 (old gaia)] |
admin:datacenter [2021/09/15 13:22] (current) peppe [Table] |
||
---|---|---|---|
Line 1: | Line 1: | ||
===== Data Center ===== | ===== Data Center ===== | ||
- | ==== Rack (top to bottom) ==== | + | ==== Rack #1 (top to bottom) ==== |
{{: | {{: | ||
Line 46: | Line 46: | ||
^ Name ^ Services | ^ Name ^ Services | ||
| FIXME | | | | FIXME | | | ||
+ | |||
+ | 3x iSCSI disks for uranus: | ||
+ | Port #3 to EMC VNXe3100 SPA port #3 | ||
+ | Port #4 to EMC VNXe3100 SPB port #3 | ||
---- | ---- | ||
Line 95: | Line 99: | ||
==== EMC VNXe3100 (NAS) ==== | ==== EMC VNXe3100 (NAS) ==== | ||
+ | |||
+ | 8GB RAM, 18x1TB NL-SAS, 3xRAID6(6-disk) groups, 3x3.7TB usable. | ||
+ | |||
+ | Serial console to SPA @9600 from Lazarus FreeBSD guest ("tip com1" | ||
+ | |||
+ | Restart failed management services: | ||
+ | # svc_restart_service restart MGMT | ||
+ | |||
+ | Check peer SP: | ||
+ | # ping peer | ||
+ | |||
+ | Shutdown: | ||
+ | # svc_shutdown --system-halt | ||
+ | | ||
+ | |||
+ | Diag: | ||
+ | # svc_diag --state=basic | ||
+ | # svc_diag --state=software | ||
+ | # svc_sysstatus | ||
FIXME Change UTP redundant cables to ESXI #2 (iSCSI). | FIXME Change UTP redundant cables to ESXI #2 (iSCSI). | ||
Line 210: | Line 233: | ||
==== Hp Procurve 2848 J4904A Switch ==== | ==== Hp Procurve 2848 J4904A Switch ==== | ||
+ | |||
+ | IP: 10.1.2.253 | ||
{{tablelayout? | {{tablelayout? | ||
Line 269: | Line 294: | ||
==== Cisco SG200-26 Gigabit Smart Switch ==== | ==== Cisco SG200-26 Gigabit Smart Switch ==== | ||
+ | |||
+ | IP: 10.1.2.254 | ||
{{tablelayout? | {{tablelayout? | ||
Line 288: | Line 315: | ||
^ 15 | ^ 15 | ||
^ 16 | ^ 16 | ||
- | ^ 17 | + | ^ 17 |
^ 18 | ^ 18 | ||
^ 19 | ^ 19 | ||
Line 345: | Line 372: | ||
---- | ---- | ||
+ | |||
+ | ==== Rack #2 (top to bottom) ==== | ||
+ | |||
+ | === HP Procurve 2680 === | ||
+ | IP: 10.1.2.254 | ||
+ | |||
==== Out of rack ==== | ==== Out of rack ==== | ||
Line 371: | Line 404: | ||
=== Sun Fire v480 (zeus) === | === Sun Fire v480 (zeus) === | ||
{{tablelayout? | {{tablelayout? | ||
- | ^ Name ^ old gaia ^ | + | ^ Name ^ old zeus ^ |
^ Services | ^ Services | ||
^ OS | Solaris/ | ^ OS | Solaris/ | ||
Line 395: | Line 428: | ||
^ Name ^ old gaia ^ | ^ Name ^ old gaia ^ | ||
^ Services | ^ Services | ||
- | ^ OS | -- | | + | ^ OS | ESXi 5.5U3 | |
^ IP | -- | | ^ IP | -- | | ||
^ iLO | 10.1.2.101 | ^ iLO | 10.1.2.101 | ||
Line 402: | Line 435: | ||
^ Model | DL380G6 | ^ Model | DL380G6 | ||
^ CPU(s) | ^ CPU(s) | ||
- | ^ RAM | + | ^ RAM |
^ Storage | ^ Storage | ||
^ P/N | 470065-082 | ^ P/N | 470065-082 | ||
Line 422: | Line 455: | ||
6/6/2019 Εγκατάσταση ESXi 5.5 και ενημέρωση σε 5.5U3 που λειτουργεί σωστά με το cache module (χωρίς μπαταρία). Επιπλέον εγκατάσταση esxui για web πρόσβαση στη διαχείριση. | 6/6/2019 Εγκατάσταση ESXi 5.5 και ενημέρωση σε 5.5U3 που λειτουργεί σωστά με το cache module (χωρίς μπαταρία). Επιπλέον εγκατάσταση esxui για web πρόσβαση στη διαχείριση. | ||
+ | |||
+ | 13/6/2019 Δίσκοι: | ||
---- | ---- |